Your passengers want and need the convenience of 110 or 220VAC electrical power in the cabin to remain productive, use and recharge their PEDs (Portable Electronic Devices) or just provide a more enjoyable and entertaining in-flight experience. The question remains; how to supply this electrical power safely? Mid Continent Controls offers an AC Power Controller which is designed specifically for the aircraft environment and controls the distribution of AC power to MC2 electrical outlets located within the aircraft cabin. Simply put, the AC outlets within the cabin of the aircraft are supplied with current only when the appropriate electrical plug is inserted. Once the plug is removed, our Power Controller halts the flow of electrical current to the outlet.
A remote turn-on signal from our Power Controller is used to regulate the flow of electrical current to cabin outlets, and these output control signals are continuously monitored for fault conditions which will automatically turn off in the event of an unsafe condition. Additionally, dedicated sensing circuitry constantly monitors the amount of AC current passing through each output. If any of the output's operational current limits are exceeded, the unit will disable that individual output and indicate a "tripped" status on its respective LED. Compact, lightweight and easy to install, AC Power Controllers from Mid Continent Controls will supply your passengers with the electrical power they need while providing the safety you demand.

The drawing to the right is in a "Scalable Vector Graphic" (SVG) Format:
Panning: Hold the alt key and click-and-drag with the mouse to pan an SVG image. When the scroll lock is enabled and Adobe SVG Viewer has the focus, the arrow keys may be used to pan the image.

Zooming: Hold the control key and click to zoom in at the mouse pointer location.
Hold the control key and click-and-drag to select a region to zoom into. Hold the control and shift keys and click to zoom out. You may also right click on the image for zoom commands in the menu. For more help, please click here.

User-Interactive Window

DC SECTION
Supply Voltage:
Nominal ................................................................................................. 28VDC
Maximum .............................................................................................. 32VDC
Minimum ............................................................................................... 22VDC

Supply Current:
Maximum .......................................................... 120mA + (Pin 5 Output Current)
Nominal ............................................................... 30mA + (Pin 5 Output Current)
Recommended 28V Circuit Breaker ................................................................ 1A

AC SECTION:
AC Voltage:
Maximum ............................................................................................ 240VAC

AC Input Current:
AC Circuit Breaker ...................................................................................... 15A
Maximum ................................................................................................... 15A
Nominal ................................................ 0.397mA@110VAC, 0.487mA@220VAC

AC Output Current:
Each output internally limited to ............................…. 5A@110VAC, 3A@220VAC

GENERAL:
Temperature:
Operating ............................ -5.0ºF. to +140ºF. / -15ºC to +60ºC @ 80% Humidity

Weight ........................................................................................ 14oz. / 369.9g

Dimensions (U.S. Standard) ......................... 3.61in. (W) x 7.72in. (L) x 1.45in. (H)
Dimensions (Metric) ........................ 91.69mm (W) x 196.09mm (L) x 36.83mm (H)

ORDER NUMBER ................................................................................106282-1